{"id":11198,"date":"2020-01-24T17:34:34","date_gmt":"2020-01-24T22:34:34","guid":{"rendered":"https:\/\/blogs.sw.siemens.com\/solidedge\/?p=11198"},"modified":"2026-03-26T07:31:01","modified_gmt":"2026-03-26T11:31:01","slug":"solid-edge-tips-and-tricks-from-forum-users-30","status":"publish","type":"post","link":"https:\/\/blogs.sw.siemens.com\/solidedge\/solid-edge-tips-and-tricks-from-forum-users-30\/","title":{"rendered":"Solid Edge Tips and Tricks from Forum Users #30"},"content":{"rendered":"\n<p>An assortment of short tips and tricks based on the discussions in the&nbsp;<a rel=\"noreferrer noopener\" href=\"https:\/\/community.sw.siemens.com\/s\/topic\/0TO4O000000MihiWAC\/solid-edge\" target=\"_blank\">Solid Edge forum<\/a>.&nbsp;<\/p>\n\n\n\n<p><a rel=\"noreferrer noopener\" href=\"http:\/\/www.surfandcode.in\/2014\/01\/index-of-all-tutorials-on-this-solid.html\" target=\"_blank\"><strong>Compiled by Tushar Suradkar<\/strong><\/a> <br>Due credit is given to respective contributors.<\/p>\n\n\n\n<p>A quick list of the previous compilations:<\/p>\n\n\n\n<p><br>\n<a href=\"https:\/\/community.plm.automation.siemens.com\/t5\/Solid-Edge-Blog\/Solid-Edge-Tips-and-Tricks-1\/ba-p\/289915\" target=\"_blank\" rel=\"noreferrer noopener\">T&amp;T #01<\/a>,&nbsp;<a href=\"https:\/\/community.plm.automation.siemens.com\/t5\/Solid-Edge-Blog\/Solid-Edge-Tips-and-Tricks-2\/ba-p\/290811\" target=\"_blank\" rel=\"noreferrer noopener\">T&amp;T #02<\/a>,&nbsp;<a href=\"https:\/\/community.plm.automation.siemens.com\/t5\/Solid-Edge-Blog\/Solid-Edge-Tips-and-Tricks-3\/ba-p\/291558\" target=\"_blank\" rel=\"noreferrer noopener\">T&amp;T #03<\/a>,&nbsp;<a href=\"https:\/\/community.plm.automation.siemens.com\/t5\/Solid-Edge-Blog\/Solid-Edge-Tips-and-Tricks-4\/ba-p\/292210\" target=\"_blank\" rel=\"noreferrer noopener\">T&amp;T #04<\/a>,&nbsp;<a href=\"https:\/\/community.plm.automation.siemens.com\/t5\/Solid-Edge-Blog\/Solid-Edge-Tips-and-Tricks-5\/ba-p\/293987\" target=\"_blank\" rel=\"noreferrer noopener\">T&amp;T #05<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/community.plm.automation.siemens.com\/t5\/Solid-Edge-Blog\/Solid-Edge-Tips-and-Tricks-6\/ba-p\/295150\" target=\"_blank\" rel=\"noreferrer noopener\">T&amp;T #06<\/a>,&nbsp;<a href=\"https:\/\/community.plm.automation.siemens.com\/t5\/Solid-Edge-Blog\/Solid-Edge-Tips-and-Tricks-7\/ba-p\/296249\" target=\"_blank\" rel=\"noreferrer noopener\">T&amp;T #07<\/a>,&nbsp;<a href=\"https:\/\/community.plm.automation.siemens.com\/t5\/Solid-Edge-Blog\/Solid-Edge-Tips-and-Tricks-8\/bc-p\/297924\" target=\"_blank\" rel=\"noreferrer noopener\">T&amp;T #08<\/a>,&nbsp;<a href=\"https:\/\/community.plm.automation.siemens.com\/t5\/Solid-Edge-Blog\/Solid-Edge-Tips-and-Tricks-9\/ba-p\/299965\" target=\"_blank\" rel=\"noreferrer noopener\">T&amp;T #09<\/a>,&nbsp;<a href=\"https:\/\/community.plm.automation.siemens.com\/t5\/Solid-Edge-Blog\/Solid-Edge-Tips-and-Tricks-10\/bc-p\/301793\" target=\"_blank\" rel=\"noreferrer noopener\">T&amp;T #10<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/community.plm.automation.siemens.com\/t5\/Solid-Edge-Blog\/Solid-Edge-Tips-and-Tricks-11\/ba-p\/303451\" target=\"_blank\" rel=\"noreferrer noopener\">T&amp;T #11<\/a>,&nbsp;<a href=\"https:\/\/community.plm.automation.siemens.com\/t5\/Solid-Edge-Blog\/Solid-Edge-Tips-and-Tricks-12\/bc-p\/309932\" target=\"_blank\" rel=\"noreferrer noopener\">T&amp;T #12<\/a>,&nbsp;<a href=\"https:\/\/community.plm.automation.siemens.com\/t5\/Solid-Edge-Blog\/Solid-Edge-Tips-and-Tricks-13\/bc-p\/314572\" target=\"_blank\" rel=\"noreferrer noopener\">T&amp;T #13<\/a>,&nbsp;<a href=\"https:\/\/community.plm.automation.siemens.com\/t5\/Solid-Edge-Blog\/Solid-Edge-Tips-and-Tricks-14\/bc-p\/324235\" target=\"_blank\" rel=\"noreferrer noopener\">T&amp;T #14<\/a>,&nbsp;<a href=\"https:\/\/community.plm.automation.siemens.com\/t5\/Solid-Edge-Blog\/Tips-and-Tricks-from-Forum-Users-15\/ba-p\/445265\" target=\"_blank\" rel=\"noreferrer noopener\">T&amp;T #15<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/community.plm.automation.siemens.com\/t5\/Solid-Edge-Blog\/Tips-and-Tricks-from-Forum-Users-16\/ba-p\/448468\" target=\"_blank\" rel=\"noreferrer noopener\">T&amp;T #16<\/a>,&nbsp;<a href=\"https:\/\/community.plm.automation.siemens.com\/t5\/Solid-Edge-Blog\/Tips-and-Tricks-from-Forum-Users-17\/ba-p\/451467\" target=\"_blank\" rel=\"noreferrer noopener\">T&amp;T #17<\/a>,&nbsp;<a href=\"https:\/\/community.plm.automation.siemens.com\/t5\/Solid-Edge-Blog\/Tips-and-Tricks-from-Forum-Users-18\/ba-p\/457430\" target=\"_blank\" rel=\"noreferrer noopener\">T&amp;T #18<\/a>,&nbsp;<a href=\"https:\/\/community.plm.automation.siemens.com\/t5\/Solid-Edge-Blog\/Tips-and-Tricks-from-Forum-Users-19\/ba-p\/508563\" target=\"_blank\" rel=\"noreferrer noopener\">T&amp;T #19<\/a>,&nbsp;<a href=\"https:\/\/community.plm.automation.siemens.com\/t5\/Solid-Edge-Blog\/Tips-and-Tricks-from-Forum-Users-20\/ba-p\/519535\" target=\"_blank\" rel=\"noreferrer noopener\">T&amp;T #20<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/community.plm.automation.siemens.com\/t5\/Solid-Edge-Blog\/Tips-and-Tricks-from-Forum-Users-21\/ba-p\/528369\" target=\"_blank\" rel=\"noreferrer noopener\">T&amp;T #21,<\/a>&nbsp;<a href=\"https:\/\/community.plm.automation.siemens.com\/t5\/Solid-Edge-Blog\/Tips-and-Tricks-from-Forum-Users-22\/ba-p\/539218\" target=\"_blank\" rel=\"noreferrer noopener\">T&amp;T #22<\/a>,&nbsp;<a href=\"https:\/\/community.plm.automation.siemens.com\/t5\/Solid-Edge-Blog\/Tips-and-Tricks-from-Forum-Users-23\/ba-p\/558706\" target=\"_blank\" rel=\"noreferrer noopener\">T&amp;T #23<\/a>,&nbsp;<a href=\"https:\/\/community.plm.automation.siemens.com\/t5\/Solid-Edge-Blog\/Tips-and-Tricks-from-Forum-Users-24\/ba-p\/577648\" target=\"_blank\" rel=\"noreferrer noopener\">T&amp;T #24<\/a>,&nbsp;<a href=\"https:\/\/blogs.sw.siemens.com\/solidedge\/tips-and-tricks-from-forum-users-25\/\" target=\"_blank\" rel=\"noreferrer noopener\">T&amp;T #25<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/blogs.sw.siemens.com\/solidedge\/tips-and-tricks-from-forum-users-26\/\">T&amp;T\n#26<\/a>, <a href=\"https:\/\/blogs.sw.siemens.com\/solidedge\/tips-and-tricks-from-forum-users-27\/\">T&amp;T\n#27<\/a>, <a href=\"https:\/\/blogs.sw.siemens.com\/solidedge\/tips-and-tricks-from-forum-users-28\/\">T&amp;T\n#28<\/a>, <a href=\"https:\/\/blogs.sw.siemens.com\/solidedge\/solid-edge-tips-and-tricks-from-the-forum-users-29\/\">T&amp;T\n#29<\/a>, <\/p>\n\n\n\n<p><strong>1.<\/strong> I have placed a part into the assembly document and have already tried to mirror it. I am facing a problem with moving or rotating the mirrored part. How do move the mirrored part to a certain place or rotate at a certain angle? Can mirrored parts even be moved?<\/p>\n\n\n\n<p><strong>Tip<\/strong>: The\nmirrored part can be moved\/rotated only after the mirror is dropped.<\/p>\n\n\n\n<p>Right-click on the Mirror\nfeature in the Pathfinder and select Drop from the context menu.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"229\" height=\"374\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/8\/2020\/01\/TnT30_01.png\" alt=\"\" class=\"wp-image-11200\" \/><\/figure><\/div>\n\n\n\n<p><strong>Contributor<\/strong>: <a href=\"https:\/\/community.sw.siemens.com\/s\/profile\/0054O000007xiJ9QAI\" target=\"_blank\" rel=\"noreferrer noopener\" aria-label=\"@TusharSuradkar (opens in a new tab)\">@TusharSuradkar<\/a><\/p>\n\n\n\n<p><strong>2.<\/strong> How\ndo I set the terminator arrows for dimensions in Draft to a smaller default\nsize? I am not able to find a setting for this value.<\/p>\n\n\n\n<p><strong>Tip:<\/strong> This is typically done in the Dimension Styles which can be accessed from the Styles button on the Home tab of the ribbon.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"486\" height=\"229\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/8\/2020\/01\/TnT30_02.png\" alt=\"\" class=\"wp-image-11201\" \/><\/figure><\/div>\n\n\n\n<p>Then, modify the dimension style<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"586\" height=\"160\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/8\/2020\/01\/TnT30_03.png\" alt=\"\" class=\"wp-image-11202\" \/><\/figure><\/div>\n\n\n\n<p>Finally, adjust the\nterminator arrows as a factor of the font size:<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"476\" height=\"277\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/8\/2020\/01\/TnT30_04.png\" alt=\"\" class=\"wp-image-11203\" \/><\/figure><\/div>\n\n\n\n<p>Ideally, perform these steps in the Draft\ntemplate so it will be available for all new drawings.<\/p>\n\n\n\n<p><strong>Contributor<\/strong>: <a rel=\"noreferrer noopener\" href=\"https:\/\/community.sw.siemens.com\/s\/profile\/0054O000007xiJ9QAI\" target=\"_blank\">@TusharSuradkar<\/a> <\/p>\n\n\n\n<p><strong>3.<\/strong> Is\nthere a way to edit links of an inter part copy? Does the part used for\nthe inter part copy have any connection with the original?<\/p>\n\n\n\n<p><strong>Tip<\/strong>: Right-click\non the Link in the Pathfinder and select Drop Parents<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"447\" height=\"445\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/8\/2020\/01\/TnT30_05.png\" alt=\"\" class=\"wp-image-11204\" srcset=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/8\/2020\/01\/TnT30_05.png 447w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/8\/2020\/01\/TnT30_05-150x150.png 150w\" sizes=\"auto, (max-width: 447px) 100vw, 447px\" \/><\/figure><\/div>\n\n\n\n<p> <strong>Contributor<\/strong>: <a rel=\"noreferrer noopener\" href=\"https:\/\/community.sw.siemens.com\/s\/profile\/0054O000007xiJ9QAI\" target=\"_blank\">@TusharSuradkar<\/a> <\/p>\n\n\n\n<p><strong>4.<\/strong> When\nI open an assembly it displays this message as shown below:<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"392\" height=\"158\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/8\/2020\/01\/TnT30_06.png\" alt=\"\" class=\"wp-image-11205\" \/><\/figure><\/div>\n\n\n\n<p>If I click No, it opens the\nfull assembly. I want to know:<\/p>\n\n\n\n<p>1. How did I get into this\nsituation in the first place?<\/p>\n\n\n\n<p>2. How to get rid of this\nmessage?<\/p>\n\n\n\n<p><strong>Tip<\/strong>: <\/p>\n\n\n\n<ol class=\"wp-block-list\"><li>There are links between the part and the assembly that need to be updated in order to open the part.<\/li><li>You could open the assembly, go to the Tools tab, and select the Inter-Part Manager. In the Inter-Part Links window select the option &#8220;Show all links&#8221; in the dropdown. Right-click on the top-level assembly within the Inter-Part Links window &amp; select the option &#8220;Break Links&#8221;, this should keep the features, but remove the links between the part and the assembly.<\/li><\/ol>\n\n\n\n<ul class=\"wp-block-list\"><li>The\nAssembly-Driven Part Features can then be deleted from the pathfinder of the\nassembly.<\/li><\/ul>\n\n\n\n<p><strong>Contributor<\/strong>: @<a href=\"https:\/\/community.sw.siemens.com\/s\/profile\/0054O000007xp6CQAQ\" target=\"_blank\" rel=\"noreferrer noopener\" aria-label=\"DaveG  (opens in a new tab)\">DaveG <\/a><\/p>\n\n\n\n<p><strong>5.<\/strong> I\nwant to know how to use the Variables of an Assembly model that is inserted\ninto another Assembly document. I want to add an assembly model into an\nassembly document, but I find that the variables of the model will be lost. How\nto solve this problem?<\/p>\n\n\n\n<p><strong>Tip<\/strong>: No. The variables from the assembly that you are dropping won&#8217;t be lost.<br> <br>Say you have inserted assembly B into assembly A. From within the assembly A, go to the Tools tab on the ribbon and click Peer Variables. Then from the Pathfinder, select the assembly B. This will show variables of assembly B. You can now right-click and Copy-Link a variable from assembly B.<br> <br>On the Tools tab of the ribbon, select *Variables* to display the local variables of the main assembly A. Now Paste-Link to link to a local variable created in the main assembly A.<br> <br>Whenever the variable from the sub-assembly B is modified, the variable in the main assembly will update to match.<\/p>\n\n\n\n<p>Here&#8217;s the video with cool background music.<\/p>\n\n\n\n<figure class=\"wp-block-embed-youtube wp-block-embed is-type-video is-provider-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Solid Edge Peer Variables\" width=\"640\" height=\"360\" src=\"https:\/\/www.youtube.com\/embed\/oE4JTVh8ow8?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<p>Hope you enjoy this video\nand learn about Peer Variables.<\/p>\n\n\n\n<p> <strong>Contributor<\/strong>: <a rel=\"noreferrer noopener\" href=\"https:\/\/community.sw.siemens.com\/s\/profile\/0054O000007xiJ9QAI\" target=\"_blank\">@TusharSuradkar<\/a> <\/p>\n\n\n\n<p> <strong>Tips<\/strong> <strong>Compiled by<a rel=\"noreferrer noopener\" href=\"http:\/\/www.surfandcode.in\/2014\/01\/index-of-all-tutorials-on-this-solid.html\" target=\"_blank\"> Tushar Suradkar<\/a><\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"http:\/\/lh3.googleusercontent.com\/-fJTAh4nzZlY\/VViROZlj_DI\/AAAAAAAALhI\/pREkqI3Lqqc\/24_thumb2_thumb_thumb_thumb_thumb_th%25255B1%25255D.png?imgmax=800\" alt=\"24_thumb2_thumb_thumb_thumb_thumb_th\" \/><\/figure>\n\n\n\n<p><a href=\"https:\/\/www.facebook.com\/groups\/solidedgeusers\/\" target=\"_blank\" rel=\"noreferrer noopener\">Join the Solid Edge User Group on Facebook<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>An assortment of short tips and tricks based on the discussions in the Solid Edge forum.<\/p>\n","protected":false},"author":42979,"featured_media":11311,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"spanish_translation":"","french_translation":"","german_translation":"","italian_translation":"","polish_translation":"","japanese_translation":"","chinese_translation":"","footnotes":""},"categories":[1,96],"tags":[],"industry":[],"product":[],"coauthors":[],"class_list":["post-11198","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news","category-tips-tricks"],"featured_image_url":"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/8\/2020\/01\/TnT30Teaser.png","_links":{"self":[{"href":"https:\/\/blogs.sw.siemens.com\/solidedge\/wp-json\/wp\/v2\/posts\/11198","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blogs.sw.siemens.com\/solidedge\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blogs.sw.siemens.com\/solidedge\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/solidedge\/wp-json\/wp\/v2\/users\/42979"}],"replies":[{"embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/solidedge\/wp-json\/wp\/v2\/comments?post=11198"}],"version-history":[{"count":3,"href":"https:\/\/blogs.sw.siemens.com\/solidedge\/wp-json\/wp\/v2\/posts\/11198\/revisions"}],"predecessor-version":[{"id":11312,"href":"https:\/\/blogs.sw.siemens.com\/solidedge\/wp-json\/wp\/v2\/posts\/11198\/revisions\/11312"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/solidedge\/wp-json\/wp\/v2\/media\/11311"}],"wp:attachment":[{"href":"https:\/\/blogs.sw.siemens.com\/solidedge\/wp-json\/wp\/v2\/media?parent=11198"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/solidedge\/wp-json\/wp\/v2\/categories?post=11198"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/solidedge\/wp-json\/wp\/v2\/tags?post=11198"},{"taxonomy":"industry","embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/solidedge\/wp-json\/wp\/v2\/industry?post=11198"},{"taxonomy":"product","embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/solidedge\/wp-json\/wp\/v2\/product?post=11198"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/solidedge\/wp-json\/wp\/v2\/coauthors?post=11198"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}