{"id":74096,"date":"2026-04-29T03:15:00","date_gmt":"2026-04-29T07:15:00","guid":{"rendered":"https:\/\/blogs.sw.siemens.com\/simcenter\/?p=74096"},"modified":"2026-05-05T17:42:05","modified_gmt":"2026-05-05T21:42:05","slug":"whats-new-simcenter-flotherm-2604","status":"publish","type":"post","link":"https:\/\/blogs.sw.siemens.com\/simcenter\/whats-new-simcenter-flotherm-2604\/","title":{"rendered":"What\u2019s new in Simcenter Flotherm 2604?"},"content":{"rendered":"\n<p>Read about the latest enhancements in the Simcenter Flotherm 2604 electronics cooling simulation software release below, or click on a topic on the index on the left.  Looking for download instructions? those are at the <a href=\"https:\/\/blogs.sw.siemens.com\/simcenter\/whats-new-simcenter-flotherm-2604\/#section_4\" data-type=\"internal\" data-id=\"#Simcenter-Flotherm-2604-download\">base<\/a> of this blog.<\/p>\n\n\n\n<div class=\"wp-block-cover is-light has-large-font-size\" style=\"min-height:127px;aspect-ratio:unset;\"><img loading=\"lazy\" decoding=\"async\" width=\"707\" height=\"136\" class=\"wp-block-cover__image-background wp-image-74105 size-full\" alt=\"\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2026\/04\/ModelComplexity-SimcenterFlotherm2604.png\" style=\"object-position:16% 59%\" data-object-fit=\"cover\" data-object-position=\"16% 59%\" srcset=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2026\/04\/ModelComplexity-SimcenterFlotherm2604.png 707w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2026\/04\/ModelComplexity-SimcenterFlotherm2604-600x115.png 600w\" sizes=\"auto, (max-width: 707px) 100vw, 707px\" \/><span aria-hidden=\"true\" class=\"wp-block-cover__background has-background-dim-30 has-background-dim\" style=\"background-color:#8fb077\"><\/span><div class=\"wp-block-cover__inner-container is-layout-constrained wp-block-cover-is-layout-constrained\">\n<p class=\"has-text-align-left has-white-color has-text-color has-link-color has-large-font-size wp-elements-506cdbbc2607efd8829781cbcba230cd\"><strong>Model the complexity<\/strong><\/p>\n<\/div><\/div>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"120\" height=\"50\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2022\/04\/LinespaceImg.png\" alt=\"\" class=\"wp-image-36805\"\/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Enhancements to Simcenter Flotherm Pack Module<\/h2>\n\n\n\n<p>Simcenter Flotherm Pack Module, introduced in <a href=\"https:\/\/blogs.sw.siemens.com\/simcenter\/whats-new-simcenter-flotherm-2504\/\" target=\"_blank\" rel=\"noreferrer noopener\">Simcenter Flotherm 2504<\/a>, is a licensed utility for creating detailed mono-chip package thermal models using a template driven approach. It integrates within your Simcenter Flotherm workflow..&nbsp; You can create detailed packages within this module and then you can also generate 2-resistor (2R) and DELPHI compact thermal models  by leveraging enabled functionality in Simcenter Flotherm\u2019s Command Center tool.<\/p>\n\n\n\n<p>So what&#8217;s new in Simcenter Flotherm Pack Module in Simcenter Flotherm 2604:<\/p>\n\n\n\n<p><strong>a) <\/strong>a PCB Template has been added, under the &#8220;other objects&#8221; tab in the initial create new package window.  <\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"351\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2026\/04\/PCBinSimcenterFlothermPackModule-1024x351.png\" alt=\"\" class=\"wp-image-74175\" srcset=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2026\/04\/PCBinSimcenterFlothermPackModule-1024x351.png 1024w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2026\/04\/PCBinSimcenterFlothermPackModule-600x205.png 600w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2026\/04\/PCBinSimcenterFlothermPackModule-768x263.png 768w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2026\/04\/PCBinSimcenterFlothermPackModule-900x308.png 900w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2026\/04\/PCBinSimcenterFlothermPackModule.png 1206w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>The wizard allows you to easily create the standard JEDEC boards \u2013 large and small with either four layers (high conductivity) or one layer (low conductivity) in the Simcenter Flotherm Pack Module utility.<\/p>\n\n\n\n<p><strong>b)<\/strong> users are able to customize DELPHI set up for advanced applications, including importing defined boundary conditions from a CSV file:<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"407\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2026\/04\/DelphiCustomEnvironment-SimcenterFlotherm2604-1024x407.png\" alt=\"\" class=\"wp-image-74176\" srcset=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2026\/04\/DelphiCustomEnvironment-SimcenterFlotherm2604-1024x407.png 1024w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2026\/04\/DelphiCustomEnvironment-SimcenterFlotherm2604-600x238.png 600w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2026\/04\/DelphiCustomEnvironment-SimcenterFlotherm2604-768x305.png 768w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2026\/04\/DelphiCustomEnvironment-SimcenterFlotherm2604-900x357.png 900w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2026\/04\/DelphiCustomEnvironment-SimcenterFlotherm2604.png 1138w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>Initially, users select<br>&#8211; The number of side nodes (max two)<br>&#8211; For peripheral leaded packages only the number of lead nodes (choice is one, two or four)<br>&#8211; The optimization method and weighting factor where appropriate<br><br>Customization can include using a defined set of boundary conditions loaded from a file. The contents of the CSV file follows a specific format. You can add comment lines at the top of the file using the # character. The data comprises several rows, each representing one boundary condition scenario or single simulation. The data in each row is then made up of a number of heat transfer coefficient values (in W\/m2K) separated by commas.<\/p>\n\n\n\n<p>After upload and selection of a boundary condition set, you use progress to the Boundary Condition Mapping section to map columns in your file to the appropriate surface nodes of the compact model (or the surface node partitioning of the detailed model). The surface nodes have drop-down selections corresponding to the number of columns in your file.<\/p>\n\n\n\n<p><strong>c)<\/strong> There is now an error histogram available to judge accuracy of your created DELPHI model in Simcenter Flotherm workflow enabled by Simcenter Flotherm Pack Module. <br><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"409\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2026\/04\/ErrorReporting-SimcenterFlothermPackModule2604-1024x409.png\" alt=\"\" class=\"wp-image-74177\" srcset=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2026\/04\/ErrorReporting-SimcenterFlothermPackModule2604-1024x409.png 1024w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2026\/04\/ErrorReporting-SimcenterFlothermPackModule2604-600x240.png 600w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2026\/04\/ErrorReporting-SimcenterFlothermPackModule2604-768x307.png 768w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2026\/04\/ErrorReporting-SimcenterFlothermPackModule2604-900x360.png 900w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2026\/04\/ErrorReporting-SimcenterFlothermPackModule2604.png 1428w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>This histogram is available after completion of the scenarios and the DELPHI model is created. It shows the errors obtained from the backfit of the compact model. The histogram displays the fraction of the number of environments corresponding to each error range, or class.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"120\" height=\"50\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2022\/04\/LinespaceImg.png\" alt=\"\" class=\"wp-image-36805\"\/><\/figure>\n\n\n\n<div class=\"wp-block-cover\" style=\"min-height:120px;aspect-ratio:unset;\"><img loading=\"lazy\" decoding=\"async\" width=\"458\" height=\"106\" class=\"wp-block-cover__image-background wp-image-74182 size-full\" alt=\"\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2026\/04\/GoFaster-SimcenterFlotherm2604.png\" data-object-fit=\"cover\"\/><span aria-hidden=\"true\" class=\"wp-block-cover__background has-background-dim\" style=\"background-color:#8d4e85\"><\/span><div class=\"wp-block-cover__inner-container is-layout-constrained wp-block-cover-is-layout-constrained\">\n<p class=\"has-text-align-left has-large-font-size\"><strong>Go Faste<\/strong>r<\/p>\n<\/div><\/div>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"120\" height=\"50\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2022\/04\/LinespaceImg.png\" alt=\"\" class=\"wp-image-36805\"\/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Export CSV data from Smartparts<\/strong><\/h2>\n\n\n\n<p>Die and fan Smartparts are popular with users. To better support users in creating a starting point for changes an export function for CSV data has been added. <\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"311\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2026\/04\/SmartPartsCSVexport-SimcenterFlotherm2604-1024x311.png\" alt=\"CSV export from Simcenter Flotherm Die and Fan Smartparts in Simcenter Flotherm 2604 release\" class=\"wp-image-74170\" srcset=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2026\/04\/SmartPartsCSVexport-SimcenterFlotherm2604-1024x311.png 1024w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2026\/04\/SmartPartsCSVexport-SimcenterFlotherm2604-600x182.png 600w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2026\/04\/SmartPartsCSVexport-SimcenterFlotherm2604-768x233.png 768w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2026\/04\/SmartPartsCSVexport-SimcenterFlotherm2604-900x273.png 900w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2026\/04\/SmartPartsCSVexport-SimcenterFlotherm2604.png 1225w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p style=\"font-size:28px\"><strong>Enhancement to viewing model attributes<\/strong><\/p>\n\n\n\n<p>To enable quick inspection of a model, you can now use a right click option to the attribute name to \u201cshow attached\u201d.&nbsp; This replicates functionality of the find operation. When selected, this highlights all the attached objects in the drawing board and the project manager.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"120\" height=\"50\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2022\/04\/LinespaceImg.png\" alt=\"\" class=\"wp-image-36805\"\/><\/figure>\n\n\n\n<div class=\"wp-block-cover is-light\" style=\"min-height:158px;aspect-ratio:unset;\"><img loading=\"lazy\" decoding=\"async\" width=\"526\" height=\"92\" class=\"wp-block-cover__image-background wp-image-74107 size-full\" alt=\"\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2026\/04\/StayIntegrated-SimcenterFlotherm2604.png\" data-object-fit=\"cover\"\/><span aria-hidden=\"true\" class=\"wp-block-cover__background has-gray-background-color has-background-dim-40 has-background-dim\"><\/span><div class=\"wp-block-cover__inner-container is-layout-constrained wp-block-cover-is-layout-constrained\">\n<p class=\"has-text-align-left has-white-color has-text-color has-link-color has-large-font-size wp-elements-848fb94ba7916bc9e7804174744cc23a\"><strong>Stay Integrated<\/strong><\/p>\n<\/div><\/div>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"120\" height=\"50\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2022\/04\/LinespaceImg.png\" alt=\"\" class=\"wp-image-36805\"\/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Additional libraries of&nbsp;ROHM Semiconductor models as Embeddable BCI-ROM<\/strong>s<\/h2>\n\n\n\n<p><strong>ROHM Semiconductor<\/strong>\u202f(Rohm&nbsp;Co.&nbsp;Ltd)&nbsp;have provided&nbsp;more components to the existing&nbsp;library of Embeddable BCI-ROM resistor shunt models initially added in <a href=\"https:\/\/blogs.sw.siemens.com\/simcenter\/whats-new-simcenter-flotherm-2510\/\" target=\"_blank\" rel=\"noreferrer noopener\">version 2510<\/a>.&nbsp;&nbsp;More models have been added to expand support to ROHM&nbsp;customers in the electronics supply chain&nbsp;who are integrating these components so they can perform thermal simulation tasks.\u202f&nbsp;These&nbsp;accurate,&nbsp;3D&nbsp;CFD ready reduced order models&nbsp;were&nbsp;generated from&nbsp;detailed thermal models&nbsp;verified to&nbsp;actual measurement&nbsp;data. They&nbsp;are included with the Simcenter&nbsp;Flotherm&nbsp;2604&nbsp;install.&nbsp;<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"507\" height=\"393\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2026\/04\/ROHM-EmbeddableBCIROM-Flotherm2604.png\" alt=\"New ROHM Semiconductor (ROHM Co Ltd) Embeddable BCI-ROM models in Simcenter Flotherm 2604 software release available in libraries under ROHM resistors folder\" class=\"wp-image-74098\"\/><\/figure><\/div>\n\n\n<p>You can access and select to use these models&nbsp;in&nbsp;your Simcenter&nbsp;Flotherm&nbsp;board and system models.&nbsp;You can learn more about&nbsp;Embeddable BCI-ROM models&nbsp;for steady state and transient simulation in this&nbsp;<a href=\"https:\/\/blogs.sw.siemens.com\/simcenter\/embeddable-bci-rom-cfd-thermal-model\/\" target=\"_blank\" rel=\"noreferrer noopener\">blog<\/a>. As a reminder,&nbsp;to use these models&nbsp;you do not need&nbsp;the additional&nbsp;BCI-ROM module, which is only&nbsp;required&nbsp;to create BCI-ROM models in each&nbsp;format<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"120\" height=\"50\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2022\/04\/LinespaceImg.png\" alt=\"\" class=\"wp-image-36805\" style=\"width:74px;height:auto\"\/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">ECXML updates<\/h2>\n\n\n\n<p>Piecewise linear isotropic conductivity support has been added, an approach for modeling non-linear temperature dependent isotropic conductivity. Simcenter Flotherm continues to stay aligned with updates to ECXML schema.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"367\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2026\/04\/ECXML-Non-linearThermalConductivity-SimcenterFlotherm2604-1024x367.png\" alt=\"Piecewise linear isotropic conductivity support in ECXML, for modeling non-linear temperature dependent isotropic conductity - Simcenter Flotherm 2604 electronics cooling simulation CFD software release.\" class=\"wp-image-74144\" srcset=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2026\/04\/ECXML-Non-linearThermalConductivity-SimcenterFlotherm2604-1024x367.png 1024w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2026\/04\/ECXML-Non-linearThermalConductivity-SimcenterFlotherm2604-600x215.png 600w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2026\/04\/ECXML-Non-linearThermalConductivity-SimcenterFlotherm2604-768x275.png 768w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2026\/04\/ECXML-Non-linearThermalConductivity-SimcenterFlotherm2604-900x323.png 900w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2026\/04\/ECXML-Non-linearThermalConductivity-SimcenterFlotherm2604.png 1177w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p id=\"Simcenter-Flotherm-2604-download\">\u2018Electronics Cooling eXtensible Markup Language\u2019 (ECXML) is a neutral file format intended to facilitate the provision of thermal models from suppliers to end users of 3D electronics cooling simulation software, such as Simcenter Flotherm and Simcenter FLOEFD. ECXML is published by JEDEC as the JEP181 guideline. To find out more about <a href=\"https:\/\/blogs.sw.siemens.com\/simcenter\/ecxml-jedec-jep181-thermal\/\" target=\"_blank\" rel=\"noreferrer noopener\">ECXML<\/a> and it\u2019s origin, please read this <a href=\"https:\/\/blogs.sw.siemens.com\/simcenter\/ecxml-jedec-jep181-thermal\/\">blog<\/a> by Robin Bornoff.<br><br>ECXML is very useful as a neutral file format and export option. However, it only supports a limited subset of wide variety of objects and Smartparts available to users of Simcenter Flotherm.&nbsp; To assist a user exporting models in this format, users can now view warnings for unsupported geometry.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\" id=\"Simcenter-Flotherm-2604-download\"><img loading=\"lazy\" decoding=\"async\" width=\"120\" height=\"50\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2022\/04\/LinespaceImg.png\" alt=\"\" class=\"wp-image-36805\" style=\"width:91px;height:auto\"\/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Where to Download Simcenter Flotherm 2604<\/h2>\n\n\n\n<p>For\u00a0<a href=\"https:\/\/plm.sw.siemens.com\/en-US\/simcenter\/fluids-thermal-simulation\/flotherm\/\" target=\"_blank\" rel=\"noreferrer noopener\">Simcenter Flotherm<\/a>\u00a0customers, please visit<strong>\u00a0<\/strong><a href=\"https:\/\/support.sw.siemens.com\/en-US\/product\/852852072\/download\/202510077\" target=\"_blank\" rel=\"noreferrer noopener\">support center<\/a>\u00a0to download\u00a0<a href=\"https:\/\/support.sw.siemens.com\/en-US\/product\/852852072\/download\/202510077\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Simcenter Flotherm 2<\/strong>604 <\/a>now and to read the release highlights documentation.\u00a0<br><br>You can also download the Simcenter Flotherm viewer from support center in it&#8217;s latest 2604 version to share with colleagues so they can view and navigate results from a file you send them.<\/p>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Read about the latest enhancements in the Simcenter Flotherm 2604 electronics cooling simulation software release below, or click on a&#8230;<\/p>\n","protected":false},"author":113871,"featured_media":74208,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"spanish_translation":"","french_translation":"","german_translation":"","italian_translation":"","polish_translation":"","japanese_translation":"","chinese_translation":"","footnotes":""},"categories":[179],"tags":[242,10824,10822,63613,63679,18631,63754],"industry":[],"product":[503],"coauthors":[63931,18630],"class_list":["post-74096","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-product-updates","tag-computational-fluid-dynamics-cfd","tag-electronics-semiconductors","tag-electronics-cooling","tag-electronics-cooling-simulation","tag-ic-package-thermal-modeling","tag-thermal-analysis","tag-thermal-simulation","product-simcenter-flotherm"],"featured_image_url":"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2026\/04\/Simcenter-Flotherm-2604B.png","_links":{"self":[{"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/posts\/74096","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/users\/113871"}],"replies":[{"embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/comments?post=74096"}],"version-history":[{"count":5,"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/posts\/74096\/revisions"}],"predecessor-version":[{"id":74299,"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/posts\/74096\/revisions\/74299"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/media\/74208"}],"wp:attachment":[{"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/media?parent=74096"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/categories?post=74096"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/tags?post=74096"},{"taxonomy":"industry","embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/industry?post=74096"},{"taxonomy":"product","embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/product?post=74096"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/coauthors?post=74096"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}