{"id":56457,"date":"2024-04-10T06:25:00","date_gmt":"2024-04-10T10:25:00","guid":{"rendered":"https:\/\/blogs.sw.siemens.com\/simcenter\/?p=56457"},"modified":"2026-03-26T06:34:33","modified_gmt":"2026-03-26T10:34:33","slug":"whats-new-simcenter-flotherm-2404-simcenter-flotherm-xt-2404","status":"publish","type":"post","link":"https:\/\/blogs.sw.siemens.com\/simcenter\/whats-new-simcenter-flotherm-2404-simcenter-flotherm-xt-2404\/","title":{"rendered":"What&#8217;s new in Simcenter Flotherm 2404 and Simcenter Flotherm XT 2404"},"content":{"rendered":"\n<p>I am pleased announce the Simcenter Flotherm 2404 and Simcenter Flotherm XT 2404 electronics cooling simulation software releases.  Please read below for an overview of release highlights.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"120\" height=\"50\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2022\/04\/LinespaceImg.png\" alt=\"\" class=\"wp-image-36805\" style=\"width:48px;height:auto\"\/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Simcenter Flotherm 2404<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"120\" height=\"50\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2022\/04\/LinespaceImg.png\" alt=\"\" class=\"wp-image-36805\" style=\"width:48px;height:auto\"\/><\/figure>\n\n\n\n<div class=\"wp-block-cover\" style=\"min-height:90px;aspect-ratio:unset;\"><span aria-hidden=\"true\" class=\"wp-block-cover__background has-background-dim\"><\/span><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"628\" class=\"wp-block-cover__image-background wp-image-56604\" alt=\"\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/Flotherm2404-ModelTheComplexity.png\" style=\"object-position:78% 34%\" data-object-fit=\"cover\" data-object-position=\"78% 34%\" srcset=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/Flotherm2404-ModelTheComplexity.png 1200w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/Flotherm2404-ModelTheComplexity-600x314.png 600w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/Flotherm2404-ModelTheComplexity-1024x536.png 1024w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/Flotherm2404-ModelTheComplexity-768x402.png 768w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/Flotherm2404-ModelTheComplexity-900x471.png 900w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><div class=\"wp-block-cover__inner-container is-layout-constrained wp-block-cover-is-layout-constrained\">\n<p class=\"has-text-align-left has-large-font-size\"><strong>Model the complexity<\/strong><\/p>\n<\/div><\/div>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"120\" height=\"50\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2022\/04\/LinespaceImg.png\" alt=\"\" class=\"wp-image-36805\" style=\"width:48px;height:auto\"\/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Introducing Material Map SmartPart in Simcenter Flotherm<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"120\" height=\"50\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2022\/04\/LinespaceImg.png\" alt=\"\" class=\"wp-image-36805\" style=\"width:48px;height:auto\"\/><\/figure>\n\n\n\n<p>A material map is a computationally efficient and accurate method to represent material variations in printed circuit boards (PCBs) copper and layers, and for modeling complex IC package substrates and metalized dies.<br><br>A material map file represents material properties as regions with sub-defined tiles that have set thermal conductivity, specific heat capacity and density values to fully represent material property variations.\u00a0 The Material Map SmartPart in Simcenter Flotherm 2404 electronics cooling software leverages imported Material Map files to enable faster, accurate modeling of modern IC packages and PCBs when compared to typical modeling approaches that consist of thousands of geometric objects.  Learn more about Material Map SmartPart in this detailed additional blog &#8221; <a href=\"https:\/\/blogs.sw.siemens.com\/simcenter\/material-map-simcenter-flotherm\/\" target=\"_blank\" rel=\"noreferrer noopener\">Leveraging a Material Map for IC package and PCB thermal analysis<\/a> &#8220;<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/blogs.sw.siemens.com\/simcenter\/material-map-simcenter-flotherm\/\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/MaterialMapSimcenterFlothermICPackage-1024x576.png\" alt=\"A study using Material Map SmartPart in Simcenter Flotherm 2404. A Die level study  providing a speed up of &gt;1000 times faster. for analysis processing steps\" class=\"wp-image-56675\" srcset=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/MaterialMapSimcenterFlothermICPackage-1024x576.png 1024w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/MaterialMapSimcenterFlothermICPackage-600x338.png 600w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/MaterialMapSimcenterFlothermICPackage-768x432.png 768w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/MaterialMapSimcenterFlothermICPackage-1536x864.png 1536w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/MaterialMapSimcenterFlothermICPackage-2048x1152.png 2048w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/MaterialMapSimcenterFlothermICPackage-395x222.png 395w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/MaterialMapSimcenterFlothermICPackage-900x506.png 900w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption class=\"wp-element-caption\">A die level study where 19 milllion cuboid objects were replaced with one Material Map SmartPart, providing a speed up of >1000 times faster for model processing operation<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Using the Material Map SmartPart for PCB and IC package thermal design workflows<\/h2>\n\n\n\n<p>Watch this video to look at how you can use the new Material Map SmartPart for a PCB thermal analysis workflow.<\/p>\n\n\n\n<figure class=\"wp-block-video\"><video controls src=\"https:\/\/videos.mentor-cdn.com\/mgc\/videos\/5400\/22c5908c-ffa3-43be-bb5b-6b0a0a6b2774-en-US-video.webm\"><\/video><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"120\" height=\"50\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2022\/04\/LinespaceImg.png\" alt=\"\" class=\"wp-image-36805\" style=\"width:161px;height:auto\"\/><\/figure>\n\n\n\n<p>IC package thermal modeling workflows are now enabled by faster modeling incorporating Material Map SmartPart modeling approach. This can then be combined with subsequent generation of secure, shareable <a href=\"https:\/\/blogs.sw.siemens.com\/simcenter\/embeddable-bci-rom-cfd-thermal-model\/\" target=\"_blank\" rel=\"noreferrer noopener\">Embeddable BCI-ROM<\/a> models for use across the electronics supply chain for 3D electronics cooling simulation of IC packages at system level in products. <\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/blogs.sw.siemens.com\/simcenter\/material-map-simcenter-flotherm\/\" target=\"_blank\" rel=\"noreferrer noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/ICpackageToSystemLevelThermalAnalysis-SimcenterFlotherm2404-1024x576.png\" alt=\"\" class=\"wp-image-56677\" srcset=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/ICpackageToSystemLevelThermalAnalysis-SimcenterFlotherm2404-1024x576.png 1024w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/ICpackageToSystemLevelThermalAnalysis-SimcenterFlotherm2404-600x338.png 600w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/ICpackageToSystemLevelThermalAnalysis-SimcenterFlotherm2404-768x432.png 768w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/ICpackageToSystemLevelThermalAnalysis-SimcenterFlotherm2404-1536x864.png 1536w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/ICpackageToSystemLevelThermalAnalysis-SimcenterFlotherm2404-2048x1152.png 2048w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/ICpackageToSystemLevelThermalAnalysis-SimcenterFlotherm2404-395x222.png 395w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/ICpackageToSystemLevelThermalAnalysis-SimcenterFlotherm2404-900x506.png 900w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<p>You can watch a video on the IC package design flow shown above in this additional <a href=\"https:\/\/blogs.sw.siemens.com\/simcenter\/material-map-simcenter-flotherm\/\" target=\"_blank\" rel=\"noreferrer noopener\">technical blog<\/a> article and explore faster thermal analysis performance.  Example studies have indicated a speed ups  of  <strong>> 1000 times faster<\/strong> for load and translation times compared to typical modeling which positively impacts overall thermal analysis process time.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"120\" height=\"50\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2022\/04\/LinespaceImg.png\" alt=\"\" class=\"wp-image-36805\" style=\"width:77px;height:auto\"\/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Simcenter Flotherm XT 2404<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"120\" height=\"50\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2022\/04\/LinespaceImg.png\" alt=\"\" class=\"wp-image-36805\" style=\"width:77px;height:auto\"\/><\/figure>\n\n\n\n<div class=\"wp-block-cover\" style=\"min-height:105px;aspect-ratio:unset;\"><span aria-hidden=\"true\" class=\"wp-block-cover__background has-background-dim-10 has-background-dim\"><\/span><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"628\" class=\"wp-block-cover__image-background wp-image-48939\" alt=\"\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2023\/04\/FlothermXTModelComplexity2_1200x628.png\" style=\"object-position:56% 100%\" data-object-fit=\"cover\" data-object-position=\"56% 100%\" srcset=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2023\/04\/FlothermXTModelComplexity2_1200x628.png 1200w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2023\/04\/FlothermXTModelComplexity2_1200x628-600x314.png 600w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2023\/04\/FlothermXTModelComplexity2_1200x628-1024x536.png 1024w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2023\/04\/FlothermXTModelComplexity2_1200x628-768x402.png 768w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2023\/04\/FlothermXTModelComplexity2_1200x628-900x471.png 900w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><div class=\"wp-block-cover__inner-container is-layout-constrained wp-block-cover-is-layout-constrained\">\n<p class=\"has-text-align-left has-large-font-size\"><strong>Model the complexity<\/strong><\/p>\n<\/div><\/div>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"120\" height=\"50\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2022\/04\/LinespaceImg.png\" alt=\"\" class=\"wp-image-36805\"\/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Quickly and easily model PCB thermal vias<\/h2>\n\n\n\n<p>New PCB thermal via modeling capabilities have been added to the Simcenter Flotherm XT EDA Bridge so you can more easily explore thermal management options:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Quickly add thermal vias under a component<\/li>\n\n\n\n<li>Thermal vias are created as a cuboid representation of an array with orthotropic material properties when transferred to Simcenter Flotherm XT<\/li>\n<\/ul>\n\n\n\n<p><br><strong>How to add a thermal via representation under a component in EDA Bridge<\/strong><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"536\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/FlothermXT2404-ThermalViaCreate-1024x536.png\" alt=\"\" class=\"wp-image-56617\" srcset=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/FlothermXT2404-ThermalViaCreate-1024x536.png 1024w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/FlothermXT2404-ThermalViaCreate-600x314.png 600w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/FlothermXT2404-ThermalViaCreate-768x402.png 768w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/FlothermXT2404-ThermalViaCreate-900x471.png 900w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/FlothermXT2404-ThermalViaCreate.png 1200w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div>\n\n\n<p><strong>How to edit PCB thermal via properties<\/strong><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"536\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/FlothermXT2404-ThermalViaEditing-1024x536.png\" alt=\"\" class=\"wp-image-56623\" srcset=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/FlothermXT2404-ThermalViaEditing-1024x536.png 1024w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/FlothermXT2404-ThermalViaEditing-600x314.png 600w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/FlothermXT2404-ThermalViaEditing-768x402.png 768w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/FlothermXT2404-ThermalViaEditing-900x471.png 900w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/FlothermXT2404-ThermalViaEditing.png 1200w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div>\n\n\n<p><strong>How do thermal vias appear in Simcenter Flotherm XT <\/strong><br><br>Once transferred to Simcenter Flotherm XT environment, the Thermal Via assembly is created within component assembly. It is named TV-\u201dComponent Designator\u201d. Geometry is created for each dielectric layer and the material  effective biaxial conductivity is calculated from via region properties<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"536\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/FlothermXT2404-ThermalViaAppearance-1024x536.png\" alt=\"\" class=\"wp-image-56619\" srcset=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/FlothermXT2404-ThermalViaAppearance-1024x536.png 1024w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/FlothermXT2404-ThermalViaAppearance-600x314.png 600w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/FlothermXT2404-ThermalViaAppearance-768x402.png 768w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/FlothermXT2404-ThermalViaAppearance-900x471.png 900w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/FlothermXT2404-ThermalViaAppearance.png 1200w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div>\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"120\" height=\"50\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2022\/04\/LinespaceImg.png\" alt=\"\" class=\"wp-image-36805\" style=\"width:74px;height:auto\"\/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Download software releases now<\/h2>\n\n\n\n<p>For existing users &#8211; please visit these support center links now:<br><br><a href=\"https:\/\/support.sw.siemens.com\/en-US\/product\/852852072\/download\/202401031\" data-type=\"link\" data-id=\"https:\/\/support.sw.siemens.com\/en-US\/product\/852852072\/download\/202401031\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">Simcenter Flotherm 2404 download<\/a><br><a href=\"https:\/\/support.sw.siemens.com\/en-US\/product\/852852076\/download\/202401029\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">Simcenter Flotherm XT 2404 download<\/a><\/p>\n\n\n\n<p style=\"font-size:26px\"><strong>Other online resources <\/strong><\/p>\n\n\n\n<p>Recent on-demand webinar topics featuring <a href=\"https:\/\/plm.sw.siemens.com\/en-US\/simcenter\/fluids-thermal-simulation\/flotherm\/\" target=\"_blank\" rel=\"noreferrer noopener\">Simcenter Flotherm <\/a>:<br>&#8211; <a href=\"http:\/\/Automate PCB thermal analysis to shorten development\" target=\"_blank\" rel=\"noreferrer noopener\">Automating PCB thermal analysis and electronics cooling simulation to shorten development<\/a><br>&#8211; <a href=\"https:\/\/webinars.sw.siemens.com\/en-US\/ic-package-thermal-simulation-embeddable-bci-rom\/\" target=\"_blank\" rel=\"noreferrer noopener\">Apply 3D reduced order IC package thermal simulation models for electronics cooling design<\/a><br><em>(features new <a href=\"https:\/\/blogs.sw.siemens.com\/simcenter\/embeddable-bci-rom-cfd-thermal-model\/\" target=\"_blank\" rel=\"noreferrer noopener\">Embeddable BCI-ROM<\/a> technology )<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Explore Material Map SmartPart in Simcenter Flotherm 2404 electronics cooling software release for fast accurate IC package and PCB thermal representation of material property variations and also improved PCB thermal vial modeling in Simcenter Flotherm XT 2404<\/p>\n","protected":false},"author":69245,"featured_media":56662,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"spanish_translation":"","french_translation":"","german_translation":"","italian_translation":"","polish_translation":"","japanese_translation":"","chinese_translation":"","footnotes":""},"categories":[179,1,182],"tags":[242,10824,63613,46970,2,10828,24062,18631],"industry":[146,145,148],"product":[503,504,505],"coauthors":[11263],"class_list":["post-56457","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-product-updates","category-news","category-tips-tricks","tag-computational-fluid-dynamics-cfd","tag-electronics-semiconductors","tag-electronics-cooling-simulation","tag-new-release","tag-product-launches","tag-simcenter-flotherm","tag-simcenter-fluids-thermal","tag-thermal-analysis","industry-consumer-industrial-electronics","industry-electronics-semiconductors","industry-semiconductor-devices","product-simcenter-flotherm","product-simcenter-flotherm-pcb","product-simcenter-flotherm-xt"],"featured_image_url":"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2024\/04\/SimcenterFlotherm2404_1920x1080A.png","_links":{"self":[{"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/posts\/56457","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/users\/69245"}],"replies":[{"embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/comments?post=56457"}],"version-history":[{"count":4,"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/posts\/56457\/revisions"}],"predecessor-version":[{"id":56807,"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/posts\/56457\/revisions\/56807"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/media\/56662"}],"wp:attachment":[{"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/media?parent=56457"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/categories?post=56457"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/tags?post=56457"},{"taxonomy":"industry","embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/industry?post=56457"},{"taxonomy":"product","embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/product?post=56457"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/coauthors?post=56457"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}