{"id":17024,"date":"2020-07-15T07:37:02","date_gmt":"2020-07-15T11:37:02","guid":{"rendered":"https:\/\/blogs.sw.siemens.com\/simcenter\/?p=17024"},"modified":"2026-03-26T06:31:26","modified_gmt":"2026-03-26T10:31:26","slug":"simcenter-flotherm-xt-2020-1-whats-new","status":"publish","type":"post","link":"https:\/\/blogs.sw.siemens.com\/simcenter\/simcenter-flotherm-xt-2020-1-whats-new\/","title":{"rendered":"Simcenter Flotherm XT 2020.1: What\u2019s new"},"content":{"rendered":"\n<p>The latest release of Simcenter Flotherm XT 2020.1 &#8211; CAD Centric electronics cooling software and sister product to Simcenter Flotherm, has just been announced. Let\u2019s take a look at new functionalities that continue to support the creation of a thermal digital twin of an electronics product during development and also enhance productivity and workflow.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Accelerating package thermal modeling &#8211; chip array added to Simcenter Flotherm Package Creator<\/strong><\/h3>\n\n\n\n<p>The prior release, Simcenter Flotherm XT 2019.3, featured the launch of <strong><a href=\"https:\/\/view.highspot.com\/viewer\/65030c15278b859cf9ba2471\" target=\"_blank\" rel=\"noreferrer noopener\">Simcenter Flotherm Package Creator<\/a><\/strong> to accelerate thermal modeling through fast and guided generation of clean CAD geometry based, detailed chip package models. Newly added to Simcenter Flotherm Package Creator is the Chip Array style (CABGA) package type under Ball Grid Array Package families. This enables engineers to quickly create Chip Array type detailed package models to integrate into 3D electronics cooling models.\u00a0\u00a0<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"538\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2020\/07\/ChipArrayCreation-1-1024x538.png\" alt=\"Chip Array Package Creation in Simcenter Flotherm Package Creator for Simcenter Flotherm XT\" class=\"wp-image-17185\" srcset=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2020\/07\/ChipArrayCreation-1-1024x538.png 1024w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2020\/07\/ChipArrayCreation-1-600x315.png 600w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2020\/07\/ChipArrayCreation-1-768x403.png 768w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2020\/07\/ChipArrayCreation-1-1110x583.png 1110w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2020\/07\/ChipArrayCreation-1.png 1200w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Creating a Chip Array type package in Simcenter Flotherm Package Creator<\/figcaption><\/figure>\n\n\n\n<p>For more information on Simcenter Flotherm Package Creator, please view the <a href=\"https:\/\/view.highspot.com\/viewer\/5f0db1f566bbaa7ed71a0088\" target=\"_blank\" aria-label=\"undefined (opens in a new tab)\" rel=\"noreferrer noopener nofollow\">fact sheet<\/a> or <a aria-label=\"undefined (opens in a new tab)\" href=\"https:\/\/www.plm.automation.siemens.com\/global\/en\/webinar\/accelerate-electronics-package-thermal-modeling\/77006\" target=\"_blank\" rel=\"noreferrer noopener\">watch<\/a> the recent recorded chip package modeling <a aria-label=\"undefined (opens in a new tab)\" href=\"https:\/\/www.plm.automation.siemens.com\/global\/en\/webinar\/accelerate-electronics-package-thermal-modeling\/77006\" target=\"_blank\" rel=\"noreferrer noopener\">on-demand webinar<\/a> that reviews appropriate package modeling vs the design stage and includes a demonstrated workflow.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Multiple heat sources on a die &#8211; Excel import<\/strong> ease of use<\/h3>\n\n\n\n<p>In response to user feedback, a faster way to build and specify power to multiple heat sources on a single die in an electronics package model has been created in Simcenter Flotherm Package Creator.&nbsp; Users can now directly import from Microsoft Excel, the data to specify position, size and power applied when creating a package.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"538\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2020\/07\/MultiheatsourceFlothermXT-1024x538.png\" alt=\"Specifying multiple heat sources on a die for a detailed package thermal model\" class=\"wp-image-17166\" srcset=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2020\/07\/MultiheatsourceFlothermXT-1024x538.png 1024w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2020\/07\/MultiheatsourceFlothermXT-600x315.png 600w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2020\/07\/MultiheatsourceFlothermXT-768x403.png 768w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2020\/07\/MultiheatsourceFlothermXT-1110x583.png 1110w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2020\/07\/MultiheatsourceFlothermXT.png 1200w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Specifying multiple heat sources on a die using Excel import in Simcenter Flotherm XT 2020.1<\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Transient electronics cooling simulation \u2013 Simplified thermostatic control <\/strong><\/h3>\n\n\n\n<p>From modern electronics, e.g smartphones and tablets, to power electronics in electric vehicles &#8211; transient thermal modeling has increasingly been adopted to better model in-use scenarios and evaluate power control strategies to go beyond the prediction of critical component temperatures for reliability purposes.<br><br>Performing full 3D transient thermal CFD analysis is computationally intensive and simulation time for long studies is often limited during competitive electronics development timescales so providing options to simplify and speed the set up, run, stop and restart of multiple transient analysis cases is very advantageous. <br><br>Transient modeling with simple thermostatic control in Simcenter Flotherm XT 2020.1 helps this in 2 related ways:<br><br>1. Using goals to stop a transient thermal analysis &#8211; Halt on Goal<br><br>Goals are possible to set as a temperature of a component, a surface, junction temperature or otherwise. To halt a simulation based on reaching, exceeding a temperature, it is as simple as setting this criteria in the \u201cSolution Control\u201d sheet now<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1010\" height=\"616\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2020\/07\/Halt-on-Goal-close.png\" alt=\"Halt Transient Simulation on Goal - Simcenter Flotherm XT\" class=\"wp-image-17207\" title=\"Illustrating halt on goal setting in Simcenter Flotherm XT\" srcset=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2020\/07\/Halt-on-Goal-close.png 1010w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2020\/07\/Halt-on-Goal-close-600x366.png 600w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2020\/07\/Halt-on-Goal-close-768x468.png 768w\" sizes=\"auto, (max-width: 1010px) 100vw, 1010px\" \/><figcaption class=\"wp-element-caption\">Halt on goal for transient simulations in Simcenter Flotherm XT<\/figcaption><\/figure>\n\n\n\n<p>The time the simulation reaches this goal during a simulation run and halted is then reported.<\/p>\n\n\n\n<p>2. Using halt on goal in a parametric study to run multiple transient simulation cases<\/p>\n\n\n\n<p>The ability to halt simulations with a goal enables more efficient scheduling of multiple transient studies as part of a parametric study. More usefully, at Simcenter Flotherm XT 2020.1, this allows you to run cases consecutively using a previously halted simulation end point as the start point for the new simulation with different logic and new halt on goal criteria applied.<\/p>\n\n\n\n<p>Consider a simple case: If you want to run a study with certain simulation control logic applied until a temperature is reached, stop the simulation, and then restart a simulation with different criteria, such as a component power setting or fan control logic option applied that would cool device until a lower temperature is reached, then you can do this easily.  Below is an example parametric study tabular set up to illustrate:<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignleft size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"538\" src=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2020\/07\/TransientParametric-1024x538.png\" alt=\"Transient parametric study: thermostatic control Simcenter Flotherm XT\" class=\"wp-image-17168\" srcset=\"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2020\/07\/TransientParametric-1024x538.png 1024w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2020\/07\/TransientParametric-600x315.png 600w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2020\/07\/TransientParametric-768x403.png 768w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2020\/07\/TransientParametric-1110x583.png 1110w, https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2020\/07\/TransientParametric.png 1200w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Parametric study for transient simulation using halt on goal criteria<\/figcaption><\/figure><\/div>\n\n\n<p>The very simple parametric study above is broken down into a base initiation case and then 3 scenarios:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Power switched off and a fan activated when temperature exceeded<\/li>\n\n\n\n<li>Power switched back on and fan deactivated when temperature reduced sufficiently<\/li>\n\n\n\n<li>Power switched off and fan activated<\/li>\n<\/ul>\n\n\n\n<p>Please view a linked <a aria-label=\"undefined (opens in a new tab)\" href=\"https:\/\/blogs.sw.siemens.com\/simcenter\/simple-thermostatic-control-in-simcenter-flotherm-xt\/\" target=\"_blank\" rel=\"noreferrer noopener\">blog<\/a> by Kelly Cordell-Morris &#8211; &#8220;<a aria-label=\"undefined (opens in a new tab)\" href=\"https:\/\/blogs.sw.siemens.com\/simcenter\/simple-thermostatic-control-in-simcenter-flotherm-xt\/\" target=\"_blank\" rel=\"noreferrer noopener\">Simple Thermostatic Control<\/a>&#8221; for a more detailed look at transient modeling using the new halt on goal capabilities in Simcenter Flotherm XT. <\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>EDA data integration \u2013 Simcenter Flotherm XT EDA bridge save\/load and library enhancements<\/strong><\/h4>\n\n\n\n<p>Simcenter Flotherm XT EDA bridge, for PCB model generation including component layout and trace, now includes the ability to save work during PCB ECAD data import process easily. This uses file extension *.edabridge. Now during a transfer or import the user is prompted if they want to save the current file or create a new file.&nbsp; Also, if a project includes a PCB transferred from EDA Bridge with components from a local library of one user and this is moved to a different user without the components in their library, then, the new user will be prompted to add the components to their own library.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Downloading Simcenter Flotherm XT 2020.1<\/strong> and other resources<\/h4>\n\n\n\n<p>For clients &#8211; please go to Siemens <a href=\"https:\/\/support.sw.siemens.com\/en-US\/signin\" target=\"_blank\" aria-label=\"undefined (opens in a new tab)\" rel=\"noreferrer noopener\">Support Center<\/a> to download the latest software release. <\/p>\n\n\n\n<p>For an introduction to package thermal modeling from simple to detailed package thermal modeling, please view the on-demand webinar: <a aria-label=\"undefined (opens in a new tab)\" href=\"https:\/\/www.plm.automation.siemens.com\/global\/en\/webinar\/accelerate-electronics-package-thermal-modeling\/77006\" target=\"_blank\" rel=\"noreferrer noopener\">Accelerate package thermal modeling in electronics cooling design<\/a><br><br>Download the factsheet on <a href=\"https:\/\/view.highspot.com\/viewer\/65030c15278b859cf9ba2471\" target=\"_blank\" rel=\"noreferrer noopener\">Simcenter Flotherm Package Creator<\/a><\/p>\n\n\n\n<p>Related Blog: <a href=\"https:\/\/blogs.sw.siemens.com\/simcenter\/simple-thermostatic-control-in-simcenter-flotherm-xt\/\" target=\"_blank\" rel=\"noreferrer noopener\">Simple Thermostatic Control<\/a> in Simcenter Flotherm XT 2020.1<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Learn about the latest in Simcenter Flotherm XT 2020.1 &#8211; CAD centric electronics cooling software including enhancements to transient simulation and parametric studies, Chip Array detailed models in Simcenter Flotherm Package Creator and more <\/p>\n","protected":false},"author":69040,"featured_media":17207,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"spanish_translation":"","french_translation":"","german_translation":"","italian_translation":"","polish_translation":"","japanese_translation":"","chinese_translation":"","footnotes":""},"categories":[1,179,182],"tags":[242,86],"industry":[89,132,133,155],"product":[505],"coauthors":[7403],"class_list":["post-17024","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news","category-product-updates","category-tips-tricks","tag-computational-fluid-dynamics-cfd","tag-simulation","industry-automotive-transportation","industry-automotive-oems","industry-automotive-suppliers","industry-industrial-machinery-heavy-equipment","product-simcenter-flotherm-xt"],"featured_image_url":"https:\/\/blogs.sw.siemens.com\/wp-content\/uploads\/sites\/6\/2020\/07\/Halt-on-Goal-close.png","_links":{"self":[{"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/posts\/17024","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/users\/69040"}],"replies":[{"embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/comments?post=17024"}],"version-history":[{"count":4,"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/posts\/17024\/revisions"}],"predecessor-version":[{"id":52012,"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/posts\/17024\/revisions\/52012"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/media\/17207"}],"wp:attachment":[{"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/media?parent=17024"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/categories?post=17024"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/tags?post=17024"},{"taxonomy":"industry","embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/industry?post=17024"},{"taxonomy":"product","embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/product?post=17024"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/simcenter\/wp-json\/wp\/v2\/coauthors?post=17024"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}