{"id":960,"date":"2014-05-12T18:25:30","date_gmt":"2014-05-13T01:25:30","guid":{"rendered":"https:\/\/blogs.plm.automation.siemens.com\/t5\/Polarion-Blog\/Morris-Medical-Monday-Polarion-MedPack-and-Regulatory-Compliance\/ba-p\/380856"},"modified":"2026-03-26T05:32:48","modified_gmt":"2026-03-26T09:32:48","slug":"morris-medical-monday-polarion-medpack-and-regulatory-compliance-part-3","status":"publish","type":"post","link":"https:\/\/blogs.sw.siemens.com\/polarion\/morris-medical-monday-polarion-medpack-and-regulatory-compliance-part-3\/","title":{"rendered":"Morris Medical Monday: Polarion MedPack and Regulatory Compliance Part 3"},"content":{"rendered":"<p>Welcome back to Morris Medical Monday: a weekly series for medical device development companies (and companies who are related to such companies), providing some useful information about <A href=\"http:\/\/www.polarion.com\/products\/index.php\" rel=\"nofollow noopener noreferrer\">Polarion solutions<\/A> and <A href=\"http:\/\/extensions.polarion.com\" rel=\"nofollow noopener noreferrer\">Polarion extensions<\/A>.<\/p>\n<p>Today we will continue on the subject of Polarion&#8217;s <A href=\"http:\/\/extensions.polarion.com\/extensions\/31-polarion-alm-medpack-iec-62304\" rel=\"nofollow noopener noreferrer\">MedPack extension<\/A>, and have a look into MedPack&#8217;s compliance support.<!--more--><br \/>\n<H2>MedPack Compliance<\/H2><br \/>\nMedPack helps medical device development projects to be compliant. The MedPack Kernel is an implementation of the <STRONG>IEC 62304<\/STRONG> (Software Lifecycle Process for Medical Devices) standard. Last week we already had a look into the rest of chapter 5.<\/p>\n<p>Today we will have a look on chapter 6 and 7 and what will be covered by Polarion MedPack:<br \/>\n<B>Mapping of IEC 62304 to MedPack<\/B><br \/>\n<TABLE style=\"text-align: left; line-height: 102%; margin-bottom: 20px;\" border=\"1\" cellspacing=\"0\" cellpadding=\"8\"><br \/>\n<THEAD><br \/>\n<TR><br \/>\n<TD style=\"background-color: #999; color: #fff;\" valign=\"middle\"><STRONG>Chapter of IEC 62304:2006<\/STRONG><\/TD><br \/>\n<TD style=\"background-color: #999; color: #fff;\" valign=\"middle\"><STRONG>Fulfilled by MedPack through:<\/STRONG><\/TD><br \/>\n<\/TR><br \/>\n<\/THEAD><br \/>\n<TBODY><br \/>\n<TR><br \/>\n<TD style=\"text-align: center; background-color: #eee; font-weight: bold;\" colspan=\"2\" valign=\"top\">6 Software maintenance PROCESS<\/TD><br \/>\n<\/TR><br \/>\n<TR><br \/>\n<TD valign=\"top\">6.1 Establish software maintenance plan<\/TD><br \/>\n<TD valign=\"top\">Wiki page:&nbsp;Software Maintenance Plan<\/TD><br \/>\n<\/TR><br \/>\n<TR><br \/>\n<TD valign=\"top\">6.2 Problem and modification analysis<\/TD><br \/>\n<TD valign=\"top\"><\/TD><br \/>\n<\/TR><br \/>\n<TR><br \/>\n<TD valign=\"top\">6.2.1 Document and EVALUATE feedback<\/TD><br \/>\n<TD valign=\"top\"><\/TD><br \/>\n<\/TR><br \/>\n<TR><br \/>\n<TD valign=\"top\">6.2.1.1 Monitor feedback<\/TD><br \/>\n<TD valign=\"top\">Feedback<\/TD><br \/>\n<\/TR><br \/>\n<TR><br \/>\n<TD valign=\"top\">6.2.1.2 Document and EVALUATE feedback<\/TD><br \/>\n<TD valign=\"top\">Feedback&nbsp;&#8211; Action,&nbsp;Problem Report&nbsp;&#8211; Attributes<\/TD><br \/>\n<\/TR><br \/>\n<TR><br \/>\n<TD valign=\"top\">6.2.1.3 Evaluate PROBLEM REPORT&#8217;S affects on SAFETY<\/TD><br \/>\n<TD valign=\"top\">Problem Report&nbsp;&#8211; Attribute<\/TD><br \/>\n<\/TR><br \/>\n<TR><br \/>\n<TD valign=\"top\">6.2.2 Use software problem resolution PROCESS<\/TD><br \/>\n<TD valign=\"top\">Polarion ALM by design<\/TD><br \/>\n<\/TR><br \/>\n<TR><br \/>\n<TD valign=\"top\">6.2.3 Analyse CHANGE REQUESTS<\/TD><br \/>\n<TD valign=\"top\">Change Request&nbsp;&#8211; Attribute<\/TD><br \/>\n<\/TR><br \/>\n<TR><br \/>\n<TD valign=\"top\">6.2.4 CHANGE REQUEST approval<\/TD><br \/>\n<TD valign=\"top\">Change Request&nbsp;&#8211; Actions<\/TD><br \/>\n<\/TR><br \/>\n<TR><br \/>\n<TD valign=\"top\">6.2.5 Communicate to users and regulators<\/TD><br \/>\n<TD valign=\"top\">Change Request&nbsp;&#8211; Attribute<\/TD><br \/>\n<\/TR><br \/>\n<TR><br \/>\n<TD valign=\"top\">6.3 Modification implementation<\/TD><br \/>\n<TD valign=\"top\"><\/TD><br \/>\n<\/TR><br \/>\n<TR><br \/>\n<TD valign=\"top\">6.3.1 Use established PROCESS to implement modification<\/TD><br \/>\n<TD valign=\"top\">Software Unit&nbsp;&#8211; Attribute<\/TD><br \/>\n<\/TR><br \/>\n<TR><br \/>\n<TD valign=\"top\">6.3.2 Re-release modified SOFTWARE SYSTEM<\/TD><br \/>\n<TD valign=\"top\">Subversion \/ Polarion ALM by design<\/TD><br \/>\n<\/TR><br \/>\n<TR><br \/>\n<TD style=\"text-align: center; background-color: #eee; font-weight: bold;\" colspan=\"2\" valign=\"top\">7 Software RISK MANAGEMENT PROCESS<\/TD><br \/>\n<\/TR><br \/>\n<TR><br \/>\n<TD valign=\"top\">7.1 Analysis of software contributing to hazardous situations<\/TD><br \/>\n<TD valign=\"top\"><\/TD><br \/>\n<\/TR><br \/>\n<TR><br \/>\n<TD valign=\"top\">7.1.1 Identify SOFTWARE ITEMS that could contribute to a hazardous situation<\/TD><br \/>\n<TD valign=\"top\">Implementation (Software System,&nbsp;Software Item,&nbsp;Software Unit,&nbsp;SOUP), link to&nbsp;Hazardous Situation<\/TD><br \/>\n<\/TR><br \/>\n<TR><br \/>\n<TD valign=\"top\">7.1.2 Identify potential causes of contribution to a hazardous situation<\/TD><br \/>\n<TD valign=\"top\">Software Item&nbsp;&#8211; Attributes<\/TD><br \/>\n<\/TR><br \/>\n<TR><br \/>\n<TD valign=\"top\">7.1.3 EVALUATE published SOUP ANOMALY lists<\/TD><br \/>\n<TD valign=\"top\">SOUP&nbsp;&#8211; Attribute \/ link role<\/TD><br \/>\n<\/TR><br \/>\n<TR><br \/>\n<TD valign=\"top\">7.1.4 Document potential causes<\/TD><br \/>\n<TD valign=\"top\">Hazardous Situation&nbsp;&#8211; Attribute<\/TD><br \/>\n<\/TR><br \/>\n<TR><br \/>\n<TD valign=\"top\">7.1.5 Document sequences of events<\/TD><br \/>\n<TD valign=\"top\">Hazardous Situation&nbsp;&#8211; Attribute<\/TD><br \/>\n<\/TR><br \/>\n<TR><br \/>\n<TD valign=\"top\">7.2 RISK CONTROL measures<\/TD><br \/>\n<TD valign=\"top\"><\/TD><br \/>\n<\/TR><br \/>\n<TR><br \/>\n<TD valign=\"top\">7.2.1 Define RISK CONTROL measures<\/TD><br \/>\n<TD valign=\"top\">Risk Control Measures<\/TD><br \/>\n<\/TR><br \/>\n<TR><br \/>\n<TD valign=\"top\">7.2.2 RISK CONTROL measures implemented in software<\/TD><br \/>\n<TD valign=\"top\">Risk Control Measure&nbsp;&#8211; Attributes Wiki page:&nbsp;Missing Traceability Report<\/TD><br \/>\n<\/TR><br \/>\n<TR><br \/>\n<TD valign=\"top\">7.3 VERIFICATION of RISK CONTROL measures<\/TD><br \/>\n<TD valign=\"top\"><\/TD><br \/>\n<\/TR><br \/>\n<TR><br \/>\n<TD valign=\"top\">7.3.1 Verify RISK CONTROL measures<\/TD><br \/>\n<TD valign=\"top\">Risk Control Measure&nbsp;&#8211; Actions<\/TD><br \/>\n<\/TR><br \/>\n<TR><br \/>\n<TD valign=\"top\">7.3.2 Document any new sequences of events<\/TD><br \/>\n<TD valign=\"top\">Risk Control Measure&nbsp;&#8211; Attributes<\/TD><br \/>\n<\/TR><br \/>\n<TR><br \/>\n<TD valign=\"top\">7.3.3 Document TRACEABILITY<\/TD><br \/>\n<TD valign=\"top\">Wiki page:&nbsp;Missing Traceability Report<\/TD><br \/>\n<\/TR><br \/>\n<TR><br \/>\n<TD valign=\"top\">7.4 RISK MANAGEMENT of software changes<\/TD><br \/>\n<TD valign=\"top\"><\/TD><br \/>\n<\/TR><br \/>\n<TR><br \/>\n<TD valign=\"top\">7.4.1 Analyse changes to MEDICAL DEVICE SOFTWARE with respect to SAFETY<\/TD><br \/>\n<TD valign=\"top\">Software Item&nbsp;&#8211; Attributes<\/TD><br \/>\n<\/TR><br \/>\n<TR><br \/>\n<TD valign=\"top\">7.4.2 Analyse impact of software changes on existing RISK CONTROL measures<\/TD><br \/>\n<TD valign=\"top\">Software Item&nbsp;&#8211; Attributes<\/TD><br \/>\n<\/TR><br \/>\n<TR><br \/>\n<TD valign=\"top\">7.4.3 Perform RISK MANAGEMENT ACTIVITIES based on analyses<\/TD><br \/>\n<TD valign=\"top\">Manual Attention: Overall risk (analysis) management is not done by MedPack<\/TD><br \/>\n<\/TR><br \/>\n<\/TBODY><br \/>\n<\/TABLE><br \/>\nFor more information about Polarion&#8217;s MedPack visit our Extension Portal using following link:<br \/>\n<A href=\"http:\/\/extensions.polarion.com\/extensions\/31-polarion-alm-medpack-iec-62304\" rel=\"nofollow noopener noreferrer\">http:\/\/extensions.polarion.com\/extensions\/31-polarion-alm-medpack-iec-62304<\/A>I hope you liked this article and you will visit our Blog again when there is another&nbsp;<B>Morris Medical Monday&nbsp;<\/B>article.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Welcome back to Morris Medical Monday: a weekly series for medical device development companies (and companies who are related to such companies), providing some useful information about Polarion sol&#8230;<\/p>\n","protected":false},"author":63333,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"spanish_translation":"","french_translation":"","german_translation":"","italian_translation":"","polish_translation":"","japanese_translation":"","chinese_translation":"","footnotes":""},"categories":[1],"tags":[],"industry":[],"product":[],"coauthors":[],"class_list":["post-960","post","type-post","status-publish","format-standard","hentry","category-news"],"_links":{"self":[{"href":"https:\/\/blogs.sw.siemens.com\/polarion\/wp-json\/wp\/v2\/posts\/960","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blogs.sw.siemens.com\/polarion\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blogs.sw.siemens.com\/polarion\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/polarion\/wp-json\/wp\/v2\/users\/63333"}],"replies":[{"embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/polarion\/wp-json\/wp\/v2\/comments?post=960"}],"version-history":[{"count":1,"href":"https:\/\/blogs.sw.siemens.com\/polarion\/wp-json\/wp\/v2\/posts\/960\/revisions"}],"predecessor-version":[{"id":961,"href":"https:\/\/blogs.sw.siemens.com\/polarion\/wp-json\/wp\/v2\/posts\/960\/revisions\/961"}],"wp:attachment":[{"href":"https:\/\/blogs.sw.siemens.com\/polarion\/wp-json\/wp\/v2\/media?parent=960"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/polarion\/wp-json\/wp\/v2\/categories?post=960"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/polarion\/wp-json\/wp\/v2\/tags?post=960"},{"taxonomy":"industry","embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/polarion\/wp-json\/wp\/v2\/industry?post=960"},{"taxonomy":"product","embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/polarion\/wp-json\/wp\/v2\/product?post=960"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/polarion\/wp-json\/wp\/v2\/coauthors?post=960"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}