{"id":1274,"date":"2014-11-03T19:20:10","date_gmt":"2014-11-04T03:20:10","guid":{"rendered":"https:\/\/blogs.plm.automation.siemens.com\/t5\/Polarion-Blog\/Morris-Medical-Monday-Work-Item-Type-34-Integration-Test-34\/ba-p\/380914"},"modified":"2026-03-26T05:37:00","modified_gmt":"2026-03-26T09:37:00","slug":"morris-medical-monday-work-item-type-integration-test","status":"publish","type":"post","link":"https:\/\/blogs.sw.siemens.com\/polarion\/morris-medical-monday-work-item-type-integration-test\/","title":{"rendered":"Morris Medical Monday: Work Item Type &#034;Integration Test&#034;"},"content":{"rendered":"<p>Welcome back to Morris Medical Monday: a weekly series for medical device development companies (and companies who are related to such companies), providing some useful information about&nbsp;<A href=\"http:\/\/www.polarion.com\/products\/index.php\" rel=\"nofollow noopener noreferrer\">Polarion solutions<\/A>&nbsp;and&nbsp;<A href=\"http:\/\/extensions.polarion.com\" rel=\"nofollow noopener noreferrer\">Polarion extensions<\/A>.<\/p>\n<p>Today we will continue on the subject of Polarion&#8217;s&nbsp;<A href=\"http:\/\/extensions.polarion.com\/extensions\/31-polarion-alm-medpack-iec-62304\" rel=\"nofollow noopener noreferrer\">MedPack extension<\/A>, and have a look into MedPack&#8217;s <EM>Integration Test<\/EM>&nbsp;Work Item type.<\/p>\n<p><!--more--><br \/>\n<H1>Integration Test<\/H1><br \/>\n<H3>Description<\/H3><br \/>\nAn integration test description according to clause 5.6.3 of the IEC 62304:2006. Any issue of this type either describes the test completely or links to test procedure descriptions or code to perform the test. It must be linked to the software item(s) and software unit(s) covered by the test. Integration tests must only be performed in case of a class B or class C project.<br \/>\n<H3 class=\"heading-1-1\"><SPAN id=\"HWorkflowSteps\">Workflow Steps<\/SPAN><\/H3><br \/>\nThe Integration Test Work Item uses the standard <SPAN class=\"wikilink\">Full Workflow<\/SPAN>.<\/p>\n<p><A href=\"http:\/\/community.plm.automation.siemens.com\/legacyfs\/online\/siemensplm_blogs\/2014\/09\/FullWorkflow_Overview.png\" rel=\"nofollow noopener noreferrer\"><IMG class=\"alignnone size-full wp-image-6494\" src=\"http:\/\/community.plm.automation.siemens.com\/legacyfs\/online\/siemensplm_blogs\/2014\/09\/FullWorkflow_Overview.png\" alt=\"FullWorkflow_Overview\" width=\"493\" height=\"50\" \/><\/A><br \/>\n<H3 class=\"heading-1-1\"><SPAN id=\"HTraceability26amp3BImpact\">Traceability &amp; Impact<\/SPAN><\/H3><br \/>\nAn Integration Test Work Item must be traceable to a <SPAN class=\"wikilink\">Software System<\/SPAN> Work Item, a <SPAN class=\"wikilink\">Software Item<\/SPAN> Work Item or a <SPAN class=\"wikilink\">SOUP<\/SPAN> Work Item. It can also be traceable to a <SPAN class=\"wikilink\">Software Unit<\/SPAN> Work Item. It has an impact on a <SPAN class=\"wikilink\">Anomaly<\/SPAN> Work Item.<br \/>\nFor more information on traceability and impacts, see the <SPAN class=\"wikilink\">Traceability wiki page<\/SPAN>.<br \/>\n<H3 class=\"heading-1-1\"><SPAN id=\"HAttributes\">Attributes<\/SPAN><\/H3><br \/>\n<H4 class=\"heading-1-1-1\"><SPAN id=\"HWorkItemAttributes\">Work Item Attributes<\/SPAN><\/H4><br \/>\nThe following custom fields must be filled out before verification can be requested:<br \/>\n<TABLE class=\"polarion-wiki-table\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"><br \/>\n<THEAD><br \/>\n<TR><br \/>\n<TH class=\"polarion-wiki-table-th\">Attribute Name<\/TH><br \/>\n<TH class=\"polarion-wiki-table-th\">Type<\/TH><br \/>\n<TH class=\"polarion-wiki-table-th\">Description<\/TH><br \/>\n<\/TR><br \/>\n<\/THEAD><br \/>\n<TBODY><br \/>\n<TR class=\"table-odd\"><br \/>\n<TD class=\"polarion-wiki-table-td\"><STRONG class=\"strong\">Test type\/content<\/STRONG><\/TD><br \/>\n<TD class=\"polarion-wiki-table-td\">Enum<\/TD><br \/>\n<TD class=\"polarion-wiki-table-td\">A Integration Test has to be classify in the the following Test type\/content:<br \/>\n&#8211; Required functionality of the software<br \/>\n&#8211; Implementation of Risk Control measures<br \/>\n&#8211; Specific timing and other behaviour<br \/>\n&#8211; Specific functioning of internal and external interfaces<br \/>\n&#8211; Testing under abnormal conditions including foreseeable misuse<br \/>\n(as required by <SPAN class=\"wikilink\">IEC 62304:2006<\/SPAN>-&gt;5.6.4 NOTE1).<\/TD><br \/>\n<\/TR><br \/>\n<TR class=\"table-even\"><br \/>\n<TD class=\"polarion-wiki-table-td\"><STRONG class=\"strong\">Pass\/Fail criteria according to test type<\/STRONG><\/TD><br \/>\n<TD class=\"polarion-wiki-table-td\">Text<\/TD><br \/>\n<TD class=\"polarion-wiki-table-td\">(as required by <SPAN class=\"wikilink\">IEC 62304:2006<\/SPAN>-&gt;5.6.4).<\/TD><br \/>\n<\/TR><br \/>\n<TR class=\"table-odd\"><br \/>\n<TD class=\"polarion-wiki-table-td\"><STRONG class=\"strong\">Tester<\/STRONG><\/TD><br \/>\n<TD class=\"polarion-wiki-table-td\">String<\/TD><br \/>\n<TD class=\"polarion-wiki-table-td\">(as required by <SPAN class=\"wikilink\">IEC 62304:2006<\/SPAN>-&gt;5.6.7c\/9.8g).<\/TD><br \/>\n<\/TR><br \/>\n<TR class=\"table-even\"><br \/>\n<TD class=\"polarion-wiki-table-td\"><STRONG class=\"strong\">Relevant test tool(s) used<\/STRONG><\/TD><br \/>\n<TD class=\"polarion-wiki-table-td\">Text<\/TD><br \/>\n<TD class=\"polarion-wiki-table-td\">(as required by <SPAN class=\"wikilink\">IEC 62304:2006<\/SPAN>-&gt;9.8e).<\/TD><br \/>\n<\/TR><br \/>\n<TR class=\"table-odd\"><br \/>\n<TD class=\"polarion-wiki-table-td\"><STRONG class=\"strong\">Test parameters to ensure repeatability<\/STRONG><\/TD><br \/>\n<TD class=\"polarion-wiki-table-td\">Text<\/TD><br \/>\n<TD class=\"polarion-wiki-table-td\">(as required by <SPAN class=\"wikilink\">IEC 62304:2006<\/SPAN>-&gt;5.6.7b NOTE \/9.8d ).<\/TD><br \/>\n<\/TR><br \/>\n<\/TBODY><br \/>\n<\/TABLE><br \/>\n<H4 class=\"heading-1-1-1\"><SPAN id=\"HVerification2FEvaluationAttributes\">Verification\/Evaluation Attributes<\/SPAN><\/H4><br \/>\nThe following custom fields must be filled out before verification\/evaluation can be finshed and the work item can be closed:<br \/>\n<TABLE class=\"polarion-wiki-table\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"><br \/>\n<THEAD><br \/>\n<TR><br \/>\n<TH class=\"polarion-wiki-table-th\">Attribute Name<\/TH><br \/>\n<TH class=\"polarion-wiki-table-th\">Type<\/TH><br \/>\n<TH class=\"polarion-wiki-table-th\">Description<\/TH><br \/>\n<\/TR><br \/>\n<\/THEAD><br \/>\n<TBODY><br \/>\n<TR class=\"table-odd\"><br \/>\n<TD class=\"polarion-wiki-table-td\"><STRONG class=\"strong\">Reviewer<\/STRONG><\/TD><br \/>\n<TD class=\"polarion-wiki-table-td\">Text<\/TD><br \/>\n<TD class=\"polarion-wiki-table-td\">Person(s) to perform, performing or have performed a review.<\/TD><br \/>\n<\/TR><br \/>\n<TR class=\"table-even\"><br \/>\n<TD class=\"polarion-wiki-table-td\"><STRONG class=\"strong\">Review summary<\/STRONG><\/TD><br \/>\n<TD class=\"polarion-wiki-table-td\">Text<\/TD><br \/>\n<TD class=\"polarion-wiki-table-td\">Short summary of the review. Attachments should be used for additional information.<\/TD><br \/>\n<\/TR><br \/>\n<TR class=\"table-odd\"><br \/>\n<TD class=\"polarion-wiki-table-td\"><STRONG class=\"strong\">Last review date<\/STRONG><\/TD><br \/>\n<TD class=\"polarion-wiki-table-td\">Date<\/TD><br \/>\n<TD class=\"polarion-wiki-table-td\">Hidden field automatically set when review has been finshed. Intended to be used for sorting and statistical analysis.<\/TD><br \/>\n<\/TR><br \/>\n<\/TBODY><br \/>\n<\/TABLE><br \/>\n<H4 class=\"heading-1-1-1\"><SPAN id=\"HEvaluationChecklist\">Evaluation Checklist<\/SPAN><\/H4><br \/>\nThe following checklist must be filled out before evaluation can be finshed and the work item can be closed:<br \/>\n<TABLE class=\"polarion-wiki-table\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"><br \/>\n<THEAD><br \/>\n<TR><br \/>\n<TH class=\"polarion-wiki-table-th\">Checklist entry<\/TH><br \/>\n<TH class=\"polarion-wiki-table-th\">Description<\/TH><br \/>\n<\/TR><br \/>\n<\/THEAD><br \/>\n<TBODY><br \/>\n<TR class=\"table-odd\"><br \/>\n<TD class=\"polarion-wiki-table-td\"><STRONG class=\"strong\">Integration has been performed in accordance with the integration plan<\/STRONG><\/TD><br \/>\n<TD class=\"polarion-wiki-table-td\">(as required by <SPAN class=\"wikilink\">IEC 62304:2006<\/SPAN>-&gt;5.6.1\/5.6.2a ).<\/TD><br \/>\n<\/TR><br \/>\n<TR class=\"table-even\"><br \/>\n<TD class=\"polarion-wiki-table-td\"><STRONG class=\"strong\">All items have been integrated into the system<\/STRONG><\/TD><br \/>\n<TD class=\"polarion-wiki-table-td\">All hardware items, software items and support for manual operations of the system have been integrated into the system (as required by <SPAN class=\"wikilink\">IEC 62304:2006<\/SPAN>-&gt;5.6.2b ).<\/TD><br \/>\n<\/TR><br \/>\n<TR class=\"table-odd\"><br \/>\n<TD class=\"polarion-wiki-table-td\"><STRONG class=\"strong\">Test passed<\/STRONG><\/TD><br \/>\n<TD class=\"polarion-wiki-table-td\">(as required by <SPAN class=\"wikilink\">IEC 62304:2006<\/SPAN>-&gt;5.6.7a ).<\/TD><br \/>\n<\/TR><br \/>\n<\/TBODY><br \/>\n<\/TABLE><br \/>\n<H4 class=\"heading-1-1-1\"><SPAN id=\"HPossibleResolutions\">Possible Resolutions<\/SPAN><\/H4><br \/>\nThe following table shows the possible resolution values when the work item is closed:<br \/>\n<TABLE class=\"polarion-wiki-table\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"><br \/>\n<THEAD><br \/>\n<TR><br \/>\n<TH class=\"polarion-wiki-table-th\">Resolution Name<\/TH><br \/>\n<TH class=\"polarion-wiki-table-th\">Description<\/TH><br \/>\n<\/TR><br \/>\n<\/THEAD><br \/>\n<TBODY><br \/>\n<TR class=\"table-odd\"><br \/>\n<TD class=\"polarion-wiki-table-td\"><STRONG class=\"strong\">Done<\/STRONG><\/TD><br \/>\n<TD class=\"polarion-wiki-table-td\">The integration test has been executed and successfully evaluated.<\/TD><br \/>\n<\/TR><br \/>\n<TR class=\"table-even\"><br \/>\n<TD class=\"polarion-wiki-table-td\"><STRONG class=\"strong\">Obsolete<\/STRONG><\/TD><br \/>\n<TD class=\"polarion-wiki-table-td\">The integration test has become obsolete and is no longer needed.<\/TD><br \/>\n<\/TR><br \/>\n<TR class=\"table-odd\"><br \/>\n<TD class=\"polarion-wiki-table-td\"><STRONG class=\"strong\">Discarded<\/STRONG><\/TD><br \/>\n<TD class=\"polarion-wiki-table-td\">The work item entry has been discarded. No further attention is needed.<\/TD><br \/>\n<\/TR><br \/>\n<\/TBODY><br \/>\n<\/TABLE><br \/>\n&nbsp;<\/p>\n<p>For more information about Polarion&#8217;s MedPack visit our Extension Portal using following link:<br \/>\n<A href=\"http:\/\/extensions.polarion.com\/extensions\/31-polarion-alm-medpack-iec-62304\" rel=\"nofollow noopener noreferrer\">http:\/\/extensions.polarion.com\/extensions\/31-polarion-alm-medpack-iec-62304<\/A>I hope you liked this article and you will visit our Blog again when there is another&nbsp;<B>Morris Medical Monday&nbsp;<\/B>article.<\/p>\n<p><HR \/><br \/>\n<P style=\"text-align: center;\"><A href=\"http:\/\/www.polarion.com\/company\/events\/webinarondemand.php?wod=Save-Time-and-Efforts-With-a-Holistic-Approach-to-Integration-Testing&amp;utm_source=morrisMedical&amp;utm_medium=web&amp;utm_campaign=blog\" rel=\"nofollow noopener noreferrer\"><IMG class=\"alignnone size-full wp-image-6738\" src=\"http:\/\/community.plm.automation.siemens.com\/legacyfs\/online\/siemensplm_blogs\/2014\/10\/polairon-holistic-integration-testing-webinar.jpg\" alt=\"Free Polarion Webinar: Save Time and Efforts With a Holistic Approach to Integration Testing\" width=\"660\" height=\"135\" \/><\/A><\/P><br \/>\n<P style=\"text-align: right; font-style: italic; font-size: smaller;\">Banner <A href=\"https:\/\/creativecommons.org\/licenses\/by\/2.0\/\" rel=\"nofollow noopener noreferrer\">photo<\/A>: flickr.com\/<A href=\"https:\/\/www.flickr.com\/photos\/jurvetson\/1627796840\/sizes\/l\" rel=\"nofollow noopener noreferrer\">Steve Jurveston<\/A><\/P><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Welcome back to Morris Medical Monday: a weekly series for medical device development companies (and companies who are related to such companies), providing some useful information about&nbsp;Polario&#8230;<\/p>\n","protected":false},"author":63333,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"spanish_translation":"","french_translation":"","german_translation":"","italian_translation":"","polish_translation":"","japanese_translation":"","chinese_translation":"","footnotes":""},"categories":[1],"tags":[],"industry":[],"product":[],"coauthors":[],"class_list":["post-1274","post","type-post","status-publish","format-standard","hentry","category-news"],"_links":{"self":[{"href":"https:\/\/blogs.sw.siemens.com\/polarion\/wp-json\/wp\/v2\/posts\/1274","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blogs.sw.siemens.com\/polarion\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blogs.sw.siemens.com\/polarion\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/polarion\/wp-json\/wp\/v2\/users\/63333"}],"replies":[{"embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/polarion\/wp-json\/wp\/v2\/comments?post=1274"}],"version-history":[{"count":1,"href":"https:\/\/blogs.sw.siemens.com\/polarion\/wp-json\/wp\/v2\/posts\/1274\/revisions"}],"predecessor-version":[{"id":1275,"href":"https:\/\/blogs.sw.siemens.com\/polarion\/wp-json\/wp\/v2\/posts\/1274\/revisions\/1275"}],"wp:attachment":[{"href":"https:\/\/blogs.sw.siemens.com\/polarion\/wp-json\/wp\/v2\/media?parent=1274"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/polarion\/wp-json\/wp\/v2\/categories?post=1274"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/polarion\/wp-json\/wp\/v2\/tags?post=1274"},{"taxonomy":"industry","embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/polarion\/wp-json\/wp\/v2\/industry?post=1274"},{"taxonomy":"product","embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/polarion\/wp-json\/wp\/v2\/product?post=1274"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/blogs.sw.siemens.com\/polarion\/wp-json\/wp\/v2\/coauthors?post=1274"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}